Film Fill Fouling Monitoring
Since its 1st introduction to the market inside 1970s, cooling structure film fill technology has significantly improved thermal performance along with reduced the size of cooling towers. However, the narrow spaces among film fill linens make them susceptible to fouling. Without correct chemical treatment, deposits can accumulate within the motion picture fill resulting in diminished tower efficiency, improved fouling and plugging from the fill. These phenomena may ultimately lead to collapse with the tower structure. This particular paper describes a fresh approach to remedy our prime efficiency film fill fouling problem in a geothermal energy power plant. The flower has a long reputation fill fouling problems as a result of very complex make-up h2o chemistry and desert-related environment conditions. In recent years, different biocide and biodispersant treatments have significantly improved fouling management by slowing down podium fill deposition charges. However, no software has been successful in lessening fill weights, specially during the summer months. Within six weeks after commencing a new control software, the average weight in the tower fill build up dropped 22% and energy performance of the cooling tower increased 20%. The therapy resulted in significant improvements in cooling tower operation and strength production efficiency. Keywords and phrases: film fill, air conditioning tower, biofouling, biocide, biodispersant, thermal productivity


In unfavourable circumstances (siting, thermal loading, normal water chemistry, etc.), best quality film fill can quickly become fouled causing the grow process to become bottlenecked. Throughout severely fouled situations the particular cooling tower complete can become so large with foulant and the greater water hold-up, that the fill may collapse in to the basin. A routine scheduled monitoring system, using either forever installed or Cooling Tower Fill transportable instrumentation, will check the motion picture fill condition frequently so that neither plant throughput or operability are jeopardized.
The DCS method of motion picture fill fouling monitoring, by way of measurement and investigation, will track the particular impact on airflow and also thermal performance, for the stacked fill pack. This method has the benefits below over methods connected with fill pack evaluating:
Does not require film fill up pack removal from your tower.
Does not require installing of load cells.
Does not require the cooling structure cell to be taken out of service for dimension.
Eliminates the humidity content error tube setteler inherent in film fill group weighing methods.
Monitors the impact on thermal performance and not just movie fill pack pounds change.